PIM Analyzers - Page 4

176 PIM Analyzers from 6 Manufacturers meet your specification.
Description:Power Amplifier / Receiver Units
Measurements:
PIM over Frequency
TX Frequeny:
698 - 2200 MHz
RX Frequency:
698 - 2200 MHz
PIM Sensitivity:
< -171 dBc
Tx Carrier Power:
50 dBm
more info
Description:925 to 960 MHz, Portable PIM Analyzer
Type:
Portable
Measurements:
PIM over Time, Noise Floor
TX Frequeny:
925 to 960 MHz
RX Frequency:
890 to 915 MHz
PIM Sensitivity:
-135 dBm
Tx Carrier Power:
24 to 46 dBm × 2 (250 mW to 40 W × 2)
more info
Description:Dual Band PCS/AWS, Battery Portable Passive Intermodulation Analyzer
Type:
Portable
Measurements:
Distance to Fault, Distance to PIM, Return Loss
TX Frequeny:
1.93 to 2.155 GHz
RX Frequency:
1.71 to 1.91 GHz
Tx Carrier Power:
20 to 43 dBm
more info
Description:Bench Top PIM Analyzer from 2.11 to 2.155 GHz (Tx) / 1.71 to 1.755 GHz (Rx)
Type:
Bench Top
Measurements:
PIM over Frequency, PIM over Time
TX Frequeny:
2.11 to 2.155 GHz
RX Frequency:
1.71 to 1.755 GHz
PIM Sensitivity:
2x 43 dBm
Tx Carrier Power:
20 to 44 dBm
more info
Type:
Bench Top
Measurements:
PIM over Frequency
TX Frequeny:
2545 - 2580 MHz
RX Frequency:
2620 - 2695 MHz
PIM Sensitivity:
< -168 dBc
Tx Carrier Power:
36 to 46 dBm
more info
Description:1.805 to 1.88 GHz, Portable PIM Analyzer
Type:
Portable
Measurements:
PIM over Time, Noise Floor
TX Frequeny:
1.805 to 1.88 GHz
RX Frequency:
1.73 to 1.95 GHz
PIM Sensitivity:
-135 dBm
Tx Carrier Power:
24 to 46 dBm × 2 (250 mW to 40 W × 2)
more info
Description:EGSM900, Battery Portable Passive Intermodulation Analyzer
Type:
Portable
Measurements:
Distance to Fault, Distance to PIM, Return Loss
TX Frequeny:
925 to 960 MHz
RX Frequency:
880 to 915 MHz
Tx Carrier Power:
20 to 43 dBm
more info
Description:Bench Top PIM Analyzer from 390 to 400 MHz (Tx) / 380 to 385 MHz (Rx)
Type:
Bench Top
Measurements:
PIM over Frequency, PIM over Time
TX Frequeny:
390 to 400 MHz
RX Frequency:
380 to 385 MHz
PIM Sensitivity:
2x 43 dBm
Tx Carrier Power:
20 to 44 dBm
more info
Description:Power Amplifier / Receiver Units
Measurements:
PIM over Frequency
TX Frequeny:
2600 - 2700 MHz
RX Frequency:
2500 - 2600 MHz
PIM Sensitivity:
< -171 dBc
Tx Carrier Power:
52 dBm
more info
Description:Portable PIM Analyzer Family with 40 W X 2 Output Power Capability
Type:
Portable
Measurements:
PIM, Return Loss
TX Frequeny:
734 to 2690 MHz
RX Frequency:
698 to 2570 MHz
PIM Sensitivity:
-135 dBm
more info

Filters

Manufacturers

Type

Measurements

PIM Sensitivity (dBm)

Apply

Tx Carrier Power (dBm)

Apply