PIM Analyzers - Page 2

176 PIM Analyzers from 6 Manufacturers meet your specification.
Description:700 to 2700 MHz, 3200 to 3600 MHz PIMD Analyzer
Type:
Bench Top
Measurements:
Noise Floor
TX Frequeny:
728 MHz to 2.69 GHz
RX Frequency:
776 MHz to 2.57 GHz
Tx Carrier Power:
44 dBm
more info
Description:700 MHz, Battery Portable Passive Intermodulation Analyzer
Type:
Portable
Measurements:
Distance to Fault, Distance to PIM, Return Loss
TX Frequeny:
728 to 764 MHz
RX Frequency:
698 to 802 MHz
Tx Carrier Power:
20 to 46 dBm
more info
MW82119A-0180 Image
Description:PIM Master MW82119A Battery-operated, High Power Portable
Type:
Portable
Measurements:
Distance to PIM, Noise Floor, PIM over Time, Swept...
TX Frequeny:
1800 to 1800 MHz
PIM Sensitivity:
-70 dBm to -130 dBm
more info
Description:Bench Top PIM Analyzer from 728 to 759 MHz (Tx) / 698 to 716 MHz (Rx)
Type:
Bench Top
Measurements:
PIM over Frequency, PIM over Time
TX Frequeny:
728 to 759 MHz
RX Frequency:
698 to 716 MHz
PIM Sensitivity:
2x 43 dBm
Tx Carrier Power:
20 to 44 dBm
more info
Type:
Bench Top
Measurements:
PIM over Frequency
TX Frequeny:
3410 - 3484 MHz
RX Frequency:
3510 - 3594 MHz
PIM Sensitivity:
< -168 dBc
Tx Carrier Power:
36 to 46 dBm
more info
Description:732 to 746 MHz, Portable PIM Analyzer
Type:
Portable
Measurements:
PIM over Time, Noise Floor
TX Frequeny:
732 to 746 MHz
RX Frequency:
698 to 804 MHz
PIM Sensitivity:
-135 dBm
Tx Carrier Power:
24 to 46 dBm × 2 (250 mW to 40 W × 2)
more info
Description:APT700 LTE, Battery Portable Passive Intermodulation Analyzer
Type:
Portable
Measurements:
Distance to Fault, Distance to PIM, Return Loss
TX Frequeny:
758 to 803 MHz
RX Frequency:
703 to 748 MHz
Tx Carrier Power:
20 to 43 dBm
more info
MW8208A-0098 Image
Description:PIM Master MW8208A for the 850 MHz cellular frequency bands
Type:
Portable
Measurements:
Distance to PIM, Noise Floor, PIM over Time, Swept...
TX Frequeny:
869 to 894 MHz
PIM Sensitivity:
-70 dBm to -130 dBm
more info
Description:Bench Top PIM Analyzer from 925 to 960 MHz (Tx) / 880 to 915 MHz (Rx)
Type:
Bench Top
Measurements:
PIM over Frequency, PIM over Time
TX Frequeny:
925 to 960 MHz
RX Frequency:
880 to 915 MHz
PIM Sensitivity:
2x 43 dBm
Tx Carrier Power:
20 to 44 dBm
more info
Description:Power Amplifier / Receiver Units
Measurements:
PIM over Frequency
TX Frequeny:
3500 - 3600 MHz
RX Frequency:
3400 - 3500 MHz
PIM Sensitivity:
< -171 dBc
Tx Carrier Power:
50 dBm
more info

Filters

Manufacturers

Type

Measurements

PIM Sensitivity (dBm)

Apply

Tx Carrier Power (dBm)