PIM Analyzers - Page 9

176 PIM Analyzers from 6 Manufacturers meet your specification.
Description:PIM Analyzers for Laboratory and QA Applications
Type:
Bench Top
Measurements:
PIM over Time, Return Loss, VSWR, Distance to Faul...
TX Frequeny:
728 to 3590 MHz
RX Frequency:
698 to 3490 MHz
PIM Sensitivity:
-172 dBc
more info
Type:
Bench Top
Measurements:
PIM over Frequency
TX Frequeny:
832 - 862 MHz
RX Frequency:
792 - 822 MHz
PIM Sensitivity:
< -168 dBc
Tx Carrier Power:
36 to 46 dBm
more info
Description:Portable PIM Analyzers with Multiple Test Modes
Type:
Portable
Measurements:
PIM over Time, Return Loss, Distance to PIM, VSWR,...
TX Frequeny:
728 to 2690 MHz
RX Frequency:
698 to 2590 MHz
PIM Sensitivity:
-172 dBm
Tx Carrier Power:
15 to 44 dBm
more info
Description:Filter Units
Type:
Rack Mounted
Measurements:
PIM over Frequency
TX Frequeny:
3410 - 3484 MHz
RX Frequency:
3510 - 3594 MHz
PIM Sensitivity:
< -171 dBc
Tx Carrier Power:
36 to 46 dBm
more info
Description:Multi Band PIM Analyzers well suited for R&D, Production & QA
Type:
Rack Mounted
Measurements:
Return Loss, Insertion Loss
TX Frequeny:
285 to 2690 MHz
RX Frequency:
410 to 1980 MHz
Tx Carrier Power:
20 to 44 dBm
more info
Type:
Bench Top
Measurements:
PIM over Frequency
TX Frequeny:
1710 - 1910 MHz
RX Frequency:
1930 - 2155 MHz
PIM Sensitivity:
< -168 dBc
Tx Carrier Power:
36 to 46 dBm
more info
Description:PIM Analyzers for TETRA and UHF 400 MHz Bands
Type:
Bench Top
Measurements:
Distance to PIM, Noise Floor, PIM over Frequency, ...
TX Frequeny:
385 to 430 MHz (385 to 400 MHz, 390 to 400 MHz, 42...
RX Frequency:
380 to 425 MHz (380 to 385 MHz, 410 to 412 MHz, 41...
PIM Sensitivity:
-165 dBc @ 2x 43 dBm carriers
Tx Carrier Power:
2x 43 dBm carriers
more info
Description:Filter Units
Type:
Rack Mounted
Measurements:
PIM over Frequency
TX Frequeny:
1710 - 1910 MHz
RX Frequency:
1930 - 2155 MHz
PIM Sensitivity:
< -171 dBc
Tx Carrier Power:
36 to 46 dBm
more info
Description:PIM Analyzers – Single Band
Type:
Bench Top
Measurements:
PIM over Time, PIM over Frequency
TX Frequeny:
2110 to 2170 MHz
RX Frequency:
1910 to 1990 MHz
PIM Sensitivity:
-165 dBc @ 2x 43 dBm carriers
Tx Carrier Power:
+20 to +44 dBm (46 dBm optional)
more info
Description:Filter Units
Type:
Rack Mounted
Measurements:
PIM over Frequency
TX Frequeny:
1850 - 1910 MHz
RX Frequency:
1930 - 1990 MHz
PIM Sensitivity:
< -171 dBc
Tx Carrier Power:
36 to 46 dBm
more info

Filters

Manufacturers

Type

Measurements